Accurate, Long-term Recording and Easy Output Settings
- 3D View
- Brochures
- Contact / Quote
- FAQ
- Overview
- Features
- Specifications
- Options
- Downloads
Hioki clamp on meters are best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CT7642 is a 2000 A AC/DC Current Sensor that pairs with the detachable Display Unit CM7290 or CM7291 to capture instantaneous waveforms that can be output to a Hioki memory recorder or logger for further analysis.
CAT IV 600 V
Key Features
- Ideal for observing instantaneous waveforms in laboratories and other temperature-controlled environments
- Ideal for site inspections by using detachable Display Unit
- Four output formats to output data to loggers or other devices (via Display Unit): WAVE, RMS, PEAK, Hz
Model No. (Order Code)
CT7642 | 2000 A AC/DC, φ55 mm (2.17 in) |
---|
Note: CT7600 series cannot be used alone. Use with the Display Unit CM7290, CM7291 to connect with Data Loggers and Memory HiCorders.When used in combination with CM7290 or CM7291, the frequency band of current display and waveform output becomes narrow.
Connect to Recorders, Data loggers, and Oscilloscopes
Must be paired with the Display Unit CM7290 or CM7291 to operate as a standalone unit. Add an output cord to deliver signals to a data logger or Memory HiCorder for the following types of output:
• A DC or AC (up to 5 kHz/10 kHz) current waveform as-is (using WAVE mode for waveform output)
• An analog signal generated by converting the input waveform to a series of RMS values (using RMS mode for RMS output)
• An analog signal generated by detecting the current waveform’s peak value (using PEAK mode for peak output
• An analog waveform generated by detecting the frequency of the current waveform (using FREQ mode for frequency output)
Broad temperature range
A wide operating temperature range of -25°C to 65°C (-13°F to 149°F)lets you use the sensor even in sub-freezing temperatures and on hot summer days.
Transfer data wirelessly using Bluetooth(R) to GENNECT Cross mobile app
Pair with the CM7291 Display Unit to send measurement data to a smartphone or tablet using Bluetooth® wireless technology. Use the GENNECT Cross dedicated app to display and review measured values and waveforms in real time.
Basic specifications
Accuracy guaranteed: 3 years
Rated measurement current | 2000 A AC/DC | |||||
---|---|---|---|---|---|---|
Max. measurement current | 2000 A (requires derating at frequency)) | |||||
Max. allowable peak input | 2840 A peak | |||||
Bandwidth | DC to 10 kHz (-3dB) (When used in combination with CM7290 or CM7291: DC 3 Hz to 1 kHz) | |||||
Typical phase accuracy | ±2.3 deg. (DC < f ≤ 66 Hz) | |||||
Output rate | 0.1 mV/A | |||||
Max. rated voltage to earth | AC/DC 600 V (CAT IV) AC/DC 1000 V (CAT III) | |||||
Core diameter | φ 55 mm (2.17 in) or less | |||||
Output connectors | HIOKI PL 14 | |||||
Operating temperature range | -25°C to 65°C (-13°F to 149°F) | |||||
Dimensions and mass | 64 mm (2.52 in)W × 195 mm (7.68 in)H × 34 mm (1.34 in)D, 510 g (18.0 oz), Cable length 2.5 m (8.20 ft) | |||||
Included accessories | None |
Display, Output (9)
EXTENSION CABLE L0220-01
2 m (6.56 ft) length
EXTENSION CABLE L0220-02
5 m (16.41 ft) length
EXTENSION CABLE L0220-03
10 m (32.81 ft) length
EXTENSION CABLE L0220-04
20 m (65.62 ft) length
EXTENSION CABLE L0220-05
30 m (98.43 ft) length
EXTENSION CABLE L0220-06
50 m (164.06 ft) length
EXTENSION CABLE L0220-07
100 m (328.11 ft) length
Case (2)
CARRYING CASE C0220
For storing sensor ×1, CM7290 ×1, AC adapter ×1, and output cord
CARRYING CASE C0221
For storing sensor ×3, CM7290 ×1, AC adapter ×1, output cord, and 30 m extension cable
Output cord (2)
OUTPUT CORD L9095
Connect to BNC terminal, 1.5 m (4.92 ft) length
OUTPUT CORD L9096
Connect to terminal block, 1.5 m (4.92 ft) length
- Brochures
- Technical Notes
- User's Guide
- Manuals
- Outline Drawings
- Certification / Declaration of Conformity
- WEEE
- Others
- Brochure: CURRENT SENSOR, PROBE Series English
- AC/DC CURRENT SENSOR CT7000 Series, DISPLAY UNIT CM7290, CM7291 English
- Combination accuracy table of CM 7290, CM 7291 and corresponding current sensor.
- AC/DC Current Sensor CT7631/CT7636/CT7642,AC/DC Auto-Zero Current Sensor CT7731/CT7736/CT7742,Display Unit CM7290/CM7291
- No results were found.
- AC/DC CURRENT SENSOR CT7642 Test Report English Ver.00
- AC/DC CURRENT SENSOR CT7631,CT7636,CT7642 Instruction Manual English Ver.01
- AC/DC CURRENT SENSOR CT7631,CT7636,CT7642 Instruction Manual Simplified Chinese Ver.01
- AC/DC CURRENT SENSOR CT7642 Ver.00
- No results were found.
- AC/DC CURRENT SENSOR CT7631,CT7636,CT7642CE
- AC/DC CURRENT SENSOR CT7631,CT7636,CT7642UKCA
- No results were found.
- No results were found.
Related Products
- MEMORY HiCORDER MR8880
- MEMORY HiCORDER MR8740
- MEMORY HiCORDER MR8870
- MEMORY HiCORDER MR8827
- MEMORY HiCORDER MR8847A
- DISPLAY UNIT CM7290
- AC/DC CURRENT SENSOR CT7636
- AC/DC CURRENT SENSOR CT7631
- DISPLAY UNIT CM7291 (Bluetooth®)
- POWER ANALYZER PW3390
- MEMORY HiCORDER MR8741
- 3CH CURRENT UNIT U8977
User Support
- Downloads Click here for brochures, manuals, technical documents, etc.
- Contact Us / Get a Quote Want help or have questions?
- Sign up for my HIOKI Join now to get access to all of our exclusive information.